Screen: 2.0-inch LCD screen, 240*320 HD IPS, high brightness LCD display;
Performance index: with carbon dioxide concentration, respiratory rate, carbon dioxide partial pressure graph;
Easy to use: Plug then use, very convenience;
Rapid assessment: Rapid end-tidal carbon dioxide assessment;
Compact design: small and portable, flexible and convenient, the curve design conforms to ergonomics;
Widely used: shockproof and drop-proof, widely used in transportation and outdoor applications:
Super long battery life: built-in lithium battery supports power bank charging, super long battery life;
Specification parameter:
All ETCO2 measurements are made after zero correction using standard gas at 5% CO2, Nz equilibrium, room temperature 25°C, atmospheric pressure 760mmHg, and flow rate of 2Umin. In the full temperature range, the stable time for ETCO2 to reach full performance is 20 minutes.
Measurement related parameters:
Sampling mode :Side stream
Sampling velocity : Range:50– 150 ml/min
Accuracy:±20% acquiesce
value:75ml/min
Initialization time :Waveform displayed in 4 seconds, reach the target within 2 minutes (25℃ at room temperature)
CO2 measurement range : 0~114 mmHg
0~15 %
0~15.2 kPa
CO2 response time :Less than 3S @ 100ml/min,Including transmission time and rise time
CO2 resolution : 0.2mmHg @ 0~59 mmHg
0.5mmHg @ 60~114 mmHg
CO2 accuracy :0~40 mmHg ±2 mmHg
41~70 mmHg ±5% reading
71~100 mmHg ±8% reading
101~114 mmHg ±10% reading High respiratory rate
80 BPM ±12% reading
CO2 stability :Short-time drift: The shift within 4 hours is less than 1 mmHg
Periodic drift : The measurement accuracy requirements are met within 120 hours
CO2 noise :5% The root mean square noise (RMS) of CO2 is less than 0.5mmHg
Data sampling rate :100Hz
Respiratory rate measurement range :3~ 150 times/minute
Respiratory rate measurement accuracy :±1 time/minute
Calibration :Users do not need to perform daily calibration
O2 compensation : Range:0~100%
Resolution:1%
Default value:16%
N2O compensation : Range:0(Off)~1(On)
Default value:Off
He compensation : Range:0(Off)~1(On)
Default value:Off
Cross sensitivity Compensating error :0~40mmHg: ±1 mmHg Additional error
41~70mmHg: ±2.5% reading Additional error
71~100 mmHg:±4% reading Additional error
101~114 mmHg:±5% reading Additional error
High-end modular Design Vital Sign Patient Monitor
●15" Color TFT LCD Screen, optional touch screen, Display Resolution: 1024* 768
●2 hours wave storage,720 hours Trend review,200 alarm events, 1000 NIBP measurement data review
●Standard interface: Maximum 9-channel waveforms display, the waveform color can be defined by user (7 colors)
●Optional interface: Maximum 14-channel waveforms display, the waveform color can be defined by user (7 colors)
●ST and 13 kinds arrhythmia analysis, pacemaker analysis, drug dose calculation
●Respiration monitoring with apnea alarms, alarm review, arrhythmia review
●Unique human voice alarm, Three Level: Low, medium and high,
Indication: Auditory and visual, All alarms can be silenced, Alarm Volume: The scope is 1~10
●Rechargeable high energy buil-in Li battery, AC/DC available, silent fanless design
●Anti - defibrillation design, NIBP over pressure protection
●Central station support Nurse Call by wire/wireless network
●Digital SpO2 with excellent performance
●Support more than 20 kinds languages
●PVI (Pleth Variability Index)
●USB support PDF file export
●The machine includes a spare parts box
High-end VItal Signs Simulator
It can be used for the production and R&D of multi-parameter (Patient Monitor,Electrocardiograph,Pulse Oximeter,Electrocardiograph,etc.) or single-parameter vital signs monitoring equipment.
Portable Anesthesia Depth Gas Multi Parameter Monitor with Disposable Emg Eeg Muscle Sensor
Portable anesthesia depth gas multi parameter monitor with disposable emg eeg muscle sensor for Anesthesia operating roomAccurate anesthesia depth index, labor pain index, myoelectric index, etc. can be obtained through fuzzylogic inference operation on brain wave signals, which can help doctors and nurses to manage anesthesiamore accurately, objectively evaluate the response and state of patients during surgery, improve surgicalsafety, and reduce surgery. risk. Effectively reduces the use of drugs, accelerates postoperative recovery time, shortens the patient's stay in PACU, reduces postoperative adverse reactions, reduces patient and hospital costs, and improves postoperative comfort for patients
MRI Compatible Non-Magnetic Patient Monitor
MRI compatible patient monitor, non-magnetic vital sign monitor, 3T MR safe monitor, MRI room anesthesia monitor. Suitable for medical imaging centers equipped with 1.5T / 3.0T superconducting MRI systems
The RG880 series vital signs simulator is an integrated, multi‑module, multi‑parameter monitoring device designed for quality control and testing of patient monitors. It is suitable for medical equipment testing laboratories, manufacturers, and healthcare institutions to measure parameters such as heart rate, blood pressure, pulse oximetry, respiratory rate, and body temperature in multi‑parameter monitors.
12.1"multi-parameter patient monitor
Standard Configuration
SpO2,PR/HR,NIBP,ECG,RESP,2-TEMP
Optional Configuration
Handheld pulse oximeter
Application Range Adult, Pediatric,Neonatal
Display 3.5 inch high-resolution TFT screen
Dimension 81.7mm*27.9mm*152.2mm
3-lead ECG, MASIMO SpO2,NIBP, HR, Temp(Single Channel),
Apnea awaking, Oxygen concentration
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature-1
Optional: Nellcor SpO2, EtCO2,IBP-1/2, Touch screen, Thermal Recorder, Wall mount, Trolley, Central station,HDMI,Temperature-2
8" color TFT LCD screen, resolution 800*600
Waterproof design, resistance to dropping (1 meter)
Low power consumption, fanless structure which creates no noise
Support external 13-20V DC power, continuously working
GET A FREE QUOTE
CONTACT US
Add : Room 1916, Building 1, Xinghuo E Square, No.20 Xinghuo Road, Jiangbei New District, Nanjing210031, China
GET A FREE QUOTE
%E7%AC%AC%E4%B8%80%EF%BC%8C%E6%9C%80%EF%BC%8C%E4%BC%98%E7%A7%80%EF%BC%8C%E5%A2%9E%E5%BC%BA%EF%BC%8C%E4%B8%80%E6%B5%81%EF%BC%8C%E5%8D%93%E8%B6%8A%EF%BC%8C%E9%A2%86%E5%85%88%EF%BC%8C%E5%85%88%E8%BF%9B%EF%BC%8C%E5%BC%95%E9%A2%86
Sorry,当前栏目暂无内容!
您可以查看其他栏目或返回 首页
Sorry,The current column has no content!
You can view other columns or return Home