●15" Color TFT LCD Screen, optional touch screen, Display Resolution: 1024* 768 ●2 hours wave storage,720 hours Trend review,200 alarm events, 1000 NIBP measurement data review ●Standard interface: Maximum 9-channel waveforms display, the waveform color can be defined by user (7 colors) ●Optional interface: Maximum 14-channel waveforms display, the waveform color can be defined by user (7 colors) ●ST and 13 kinds arrhythmia analysis, pacemaker analysis, drug dose calculation ●Respiration monitoring with apnea alarms, alarm review, arrhythmia review ●Unique human voice alarm, Three Level: Low, medium and high, Indication: Auditory and visual, All alarms can be silenced, Alarm Volume: The scope is 1~10 ●Rechargeable high energy buil-in Li battery, AC/DC available, silent fanless design ●Anti - defibrillation design, NIBP over pressure protection ●Central station support Nurse Call by wire/wireless network ●Digital SpO2 with excellent performance ●Support more than 20 kinds languages ●PVI (Pleth Variability Index) ●USB support PDF file export ●The machine includes a spare parts box

Classification :

Features

●15" Color TFT LCD Screen, optional touch screen, Display Resolution: 1024* 768

●2 hours wave storage,720 hours Trend review,200 alarm events, 1000 NIBP measurement data review

●Standard interface: Maximum 9-channel waveforms display, the waveform color can be defined by user (7 colors)

●Optional interface: Maximum 14-channel waveforms display, the waveform color can be defined by user (7 colors)

●ST and 13 kinds arrhythmia analysis, pacemaker analysis, drug dose calculation

●Respiration monitoring with apnea alarms, alarm review, arrhythmia review

●Unique human voice alarm, Three Level: Low, medium and high, 

Indication: Auditory and visual, All alarms can be silenced, Alarm Volume: The scope is 1~10

●Rechargeable high energy buil-in Li battery, AC/DC available, silent fanless design

●Anti - defibrillation design, NIBP over pressure protection

●Central station support Nurse Call by wire/wireless network

●Digital SpO2 with excellent performance

●Support more than 20 kinds languages

●PVI (Pleth Variability Index)

●USB support PDF file export

●The machine includes a spare parts box

 

Technical Specifications

Quality Standards and Classification: ISO13485,ISO9001,CFDA,FSC 

MDD classification: Class II b

Anti-electroshock degree: Class I equipment

(internal power supply)

TEMP/SpO2 /NIBP: BF

ECG/Resp: CF

 

Application Range

Adult/Pediatric/Neonatal/Medicine/Surgery/

Operating Room/ICU/CCU/Clinic/Ambulance/

Emergency Centers/Bedside Care Ward/Family Care

 

Environment

Temperature

Working:0 ~ 40℃

Storage: -20 ~ 50℃

Humidity

Working: 15% - 90%

Storage: 15% - 90% (no coagulation)

Atmospheric pressure

Working: 86.0kPa ~ 106.0kPa

Storage: 86.0kPa ~ 106.0kPa

Power Requirement

External power required

AC: 100V ~ 240V, 50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 14.8V, 2200mAh rechargeable Li-ion battery

2h operating after full charge

5min operating after low battery alarm

Input power: Pmax=90VA

FUSE: T1.5AL 250V

 

 

 

Dimension and Weight

Equipment: 350mm x 155mm x320mm(about); 4.5kg(about)

Package: 430mm x 315mm x 400mm; 7.7kg(about)

 

Storage

Trend         720 hours

NIBP review    1000 NIBP events

Wave review    2 hours

Alarm review   200 alarm events

All storage data are non volatile

 

ECG 

5 Leads: RA, LA,LL, RL, V

lead mode: I, I, II, AVR, AVL, AVF, V

3Leads:R,L,F or RA,LA, LL

Lead mode: I, II, II

Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

Sweep speed: 12 .5mm/s, 25mm/s, 50mm/s

Bandwidth

Surgery: 1 ~ 20Hz

Monitor: 0.5 ~ 40Hz

Diagnostic: 0.05 ~ 130Hz

Calibration Signal: 1(mVp-p), Accuracy: 5%

CMRR

Diagnostic Mode: >90dB

Monitor Mode: > 110dB

Surgery Mode: >110dB

Electrode offset potential: ±300mV

Leakage Current: <10 uA

 

HR Measure Range

Adult: 15 ~ 300 bpm

Neonatal/Pediatric: 15 ~ 350 bpm

Accuracy: ±1%

Resolution: 1bpm

Sensitivity: >200 (uVp-p)

Differential Input Impedance: >5 MΩ

 

ST Segment

ST Segment Monitoring Range

Measure and Alarm: -2.0 ~ +2.0mV

Accuracy: -0.8mV ~ +0.8mV

±0.02mV or ±10%,which is greater

 

ARR Detecting

Type: ASYSTOLE, VFIBNTAC, COUPLET, BIGEMINY,

TRIGEMINY, R ON T, VT>2, BRADY, MISSED BEATS,

PNP, PNC, Alarm Available, Review Available

 

NIBP

Method: Oscillometry

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1,2,3, 4,5, 10, 15, 

30, 60, 90,120, 180,

240, 480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240bpm

Alarm Type: SYS, DIA, MEAN

 

 

Measuring and alarm range:

Adult Mode: SYS 40 ~ 280mmHg

DIA 10 ~ 220mmHg

MEAN 20 ~ 240mmHg

Pediatric Mode: SYS 40 ~ 220mmHg

DIA 10 ~ 160mmHg

MEAN 20 ~ 170mmHg

Neonatal Mode: SYS 40 ~ 135mmHg

DIA 10 ~ 100mmHg

MEAN 20 ~ 110mmHg

Resolution: 1mmHg

Accuracy: Maximum Mean error ±5mmHg

Maximum Standard deviation 8mmHg

Overpressure Protection

Adult Mode: 300mmHg

Pediatric Mode: 240mmHg

Neonatal Mode: 150mmHg

Static pressure accuracy: 3mmHg

 

SpO2

Measuring Range: 0 ~ 100%

Resolution: 1%

Alarm Range: 0 ~ 100%

Accuracy: 70% ~ 100% ±2%

<69% unspecified

Actualization interval about: 1 Sec.

Alarm Delay: 10 Sec 

 

 

 

Pulse Rate

Measuring and Alarm Range: 20 ~ 250bpm

Resolution: 1bpm

Accuracy: ±3bpm

Perfusion Index

Measure and Alarm Range: 0.02 ~ 20%

Resolution: 0.01%

Respiration

Method: Impedance between R-F(RA-LL)

Measuring Impedance Range: 0.3~3Ω

Base line Impedance Range: 200~4000Ω

Bandwidth: 0.3~2.5Hz

Resp rate: Measurement Range

Adult: 0~ 120 BrP

Neonatal / Pediatric: 0 ~ 150 BrPM

Resolution: 1 BrPM

Accuracy: 0 ~ 6 BrPM: unspecified

7 ~ 150 BrPM: ±2 BrPM

Apnea Alarm: 10 ~ 40 S

Gain 0.25,0.500,1,2,4 

Differential Input Impedance: >2.5MΩ

Inspiriting current: <300 μA RMS max

TEMP

Channel: 2

Measuring and Alarm Range: 0 ~ 50℃

Resolution: 0.1℃

Accuracy: ±0.1℃ (0 ~ 50℃) 

Actualization intervalabout: 1 Sec

Average Time Constant: <10 Sec

Sensor Type: 10K series, 2.25K series

Standard Accessories Adult

NIBP cuff & Extension tube, ECG cable & electrodes,

SpO2 sensor, TEMP probe, Lithium-ion battery,

Power cable,User manual

 

Technical Specifications

IBP (optional)

Sensor

Reusable sensors: OHMEDA P23XL or BD, EDWARD compatible

Once usage: OHMEDA DT-4812 or BD, EDWARD compatible

Excitation voltage: +5Vdc ±2%

Sensitivity: 5uVN/mmHg

Channels: 2 channels

Measure Range: -50~ 360(mmHg)

Resolution: 1mmHg

Accuracy(no sensor): ±2% or ±1mmHg, use the greater

Band Width

Normal mode: DC ~ 40Hz

Smooth mode: DC ~ 12.5Hz

Measurable parameter: ART, PA, CVP, LAP, RAP, ICP

 

CO2(optional)

Measure Range: 0-150mmHg

Resolution: 1mmHg

Accuracy: 2mmHg @ < 5.0% CO2(at ATPS)

Breath Rate: 3 ~ 150 bpm

 

Recorder (optional)

Paper width: 50 mm

Paper length: 20 m

Speed: 6. 25/12.5/25/50 mm/s

Wave channel: 3 channels

 

Gas (optional Sidestream EtCO2)

RangeFiCO2,EtCO2:0-10 VOL%  10-15VOL%

RR: 0~ 0-150BPM

N20:0-100VOL%

Sevoflurane: 0-10 VOL%

Isoflurane: 0-8 VOL%

Enflurane: 0-8 VOL%

Desflurane: 0-22 VOL%

Halflurane: 0-8 VOL%

Resp: 3- 120 BPM,1BPM

O2(Optional): 0~100

Accuracy

FiCO2,EtCO2: + (0.3% +2% of reading)@(0 ~ 10%)+ (0.3% + 5% of reading)@(0 ~ 10%)

RR

N20:+1BPM:+ (2% + 5% of reading)

Sevoflurane : (0.3% + 2% of reading)@(5 ~ 10%):+ (0.3% + 2% of reading)

Desflurane

Isofurane

:+ (0.3% + 2% of reading)@(0 ~ 5%)

Enflurane: I (0.3% + 2% of reading)@(5 ~ 8%)

Halflurane:+ (0.3% + 2% of reading)

 

 

Standard:3/5-leads ECG、SpO2、NIBP、RESP、2-Temp、PR/HR

Optional:WIFI、AG、2-IBP、VGA、CMS、EtCO2、Nurse Call、Suntech Blood Pressure、

Touch Screen、Nellcor Spo2、Wall Mount、Recorder、Rolling Stand、Depth of anesthesia、Children Accessories、Newborn Accessories、Disposable Spo2 Probe 