Screen: 2.0-inch LCD screen, 240*320 HD IPS, high brightness LCD display; Performance index: with carbon dioxide concentration, respiratory rate, carbon dioxide partial pressure graph; Easy to use: Plug then use, very convenience; Rapid assessment: Rapid end-tidal carbon dioxide assessment; Compact design: small and portable, flexible and convenient, the curve design conforms to ergonomics; Widely used: shockproof and drop-proof, widely used in transportation and outdoor applications: Super long battery life: built-in lithium battery supports power bank charging, super long battery life;   Specification parameter: All ETCO2 measurements are made after zero correction using standard gas at 5% CO2, Nz equilibrium, room temperature 25°C, atmospheric pressure 760mmHg, and flow rate of 2Umin. In the full temperature range, the stable time for ETCO2 to reach full performance is 20 minutes.   Measurement related parameters: Sampling mode :Side stream Sampling velocity : Range:50– 150 ml/min  Accuracy:±20% acquiesce  value:75ml/min Initialization time :Waveform displayed in 4 seconds, reach the target within 2 minutes (25℃ at room temperature) CO2 measurement range : 0~114 mmHg  0~15 %  0~15.2 kPa CO2 response time :Less than 3S @ 100ml/min,Including transmission time and rise time CO2 resolution : 0.2mmHg @ 0~59 mmHg  0.5mmHg @ 60~114 mmHg CO2 accuracy :0~40 mmHg ±2 mmHg 41~70 mmHg ±5% reading 71~100 mmHg ±8% reading  101~114 mmHg ±10% reading High respiratory rate  80 BPM         ±12% reading CO2 stability :Short-time drift: The shift within 4 hours is less than 1 mmHg  Periodic drift : The measurement accuracy requirements are met within 120 hours CO2 noise :5% The root mean square noise (RMS) of CO2 is less than 0.5mmHg Data sampling rate :100Hz Respiratory rate measurement range :3~ 150 times/minute Respiratory rate measurement accuracy :±1 time/minute Calibration :Users do not need to perform daily calibration O2 compensation : Range:0~100%  Resolution:1%  Default value:16% N2O compensation : Range:0(Off)~1(On)  Default value:Off He compensation : Range:0(Off)~1(On)  Default value:Off Cross sensitivity Compensating error :0~40mmHg: ±1 mmHg Additional error         41~70mmHg: ±2.5% reading Additional error                                                                 71~100 mmHg:±4% reading Additional error                                                                 101~114 mmHg:±5% reading Additional error

Classification :

Feature

  1. Screen: 2.0-inch LCD screen, 240*320 HD IPS, high brightness LCD display;
  2. Performance index: with carbon dioxide concentration, respiratory rate, carbon dioxide partial pressure graph;
  3. Easy to use: Plug then use, very convenience;
  4. Rapid assessment: Rapid end-tidal carbon dioxide assessment;
  5. Compact design: small and portable, flexible and convenient, the curve design conforms to ergonomics;
  6. Widely used: shockproof and drop-proof, widely used in transportation and outdoor applications:
  7. Super long battery life: built-in lithium battery supports power bank charging, super long battery life;

 

Specification parameter:

All ETCO2 measurements are made after zero correction using standard gas at 5% CO2, Nz equilibrium, room temperature 25°C, atmospheric pressure 760mmHg, and flow rate of 2Umin. In the full temperature range, the stable time for ETCO2 to reach full performance is 20 minutes.

 

Measurement related parameters:

Sampling mode :Side stream

Sampling velocity : Range:50– 150 ml/min 

Accuracy:±20% acquiesce 

value:75ml/min

Initialization time :Waveform displayed in 4 seconds, reach the target within 2 minutes (25℃ at room temperature)

CO2 measurement range : 0~114 mmHg 

0~15 % 

0~15.2 kPa

CO2 response time :Less than 3S @ 100ml/min,Including transmission time and rise time

CO2 resolution : 0.2mmHg @ 0~59 mmHg 

0.5mmHg @ 60~114 mmHg

CO2 accuracy :0~40 mmHg ±2 mmHg

41~70 mmHg ±5% reading

71~100 mmHg ±8% reading 

101~114 mmHg ±10% reading High respiratory rate 

80 BPM         ±12% reading

CO2 stability :Short-time drift: The shift within 4 hours is less than 1 mmHg 

Periodic drift : The measurement accuracy requirements are met within 120 hours

CO2 noise :5% The root mean square noise (RMS) of CO2 is less than 0.5mmHg

Data sampling rate :100Hz

Respiratory rate measurement range :3~ 150 times/minute

Respiratory rate measurement accuracy :±1 time/minute

Calibration :Users do not need to perform daily calibration

O2 compensation : Range:0~100% 

Resolution:1% 

Default value:16%

N2O compensation : Range:0(Off)~1(On) 

Default value:Off

He compensation : Range:0(Off)~1(On) 

Default value:Off

Cross sensitivity Compensating error :0~40mmHg: ±1 mmHg Additional error 

       41~70mmHg: ±2.5% reading Additional error 

                                                               71~100 mmHg:±4% reading Additional error 

                                                               101~114 mmHg:±5% reading Additional error