• YH-D-I Non-Invasive Neonatal Jaundice Meter
  • YH-D-I Non-Invasive Neonatal Jaundice Meter
  • YH-D-I Non-Invasive Neonatal Jaundice Meter
  • YH-D-I Non-Invasive Neonatal Jaundice Meter
  • YH-D-I Non-Invasive Neonatal Jaundice Meter
  • YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter
YH-D-I Non-Invasive Neonatal Jaundice Meter

YH-D-I Non-Invasive Neonatal Jaundice Meter

这里是标题一h1占位文字

Transcutaneous Bilirubin Meter is a non-invasive diagnostic device for neonatal bilirubin screening. Widely used in maternity wards, neonatal departments, maternal and child health hospitals, community clinics and baby care centers for newborn jaundice screening.

Classification :

Product Description

YH-D-I Jaundice Meter is a non-invasive diagnostic device for neonatal bilirubin screening. Widely used in maternity wards, neonatal departments, maternal and child health hospitals, community clinics and baby care centers for newborn jaundice screening.

Adopting xenon flash lamp and optical reflection technology, it requires no blood sampling. Simply place the probe gently on the newborn’s forehead to get bilirubin reading instantly. Non-invasive design avoids pain and infection risks from blood collection, ideal for repeated continuous monitoring.

 

Application

Used in Maternity ward, neonatal department, MCH hospital, pediatric clinic, community health center, baby care center. For routine jaundice screening and post-discharge follow-up.

 

Product Advantages

✅ Non-invasive & Painless Test: No blood draw, instant result, suitable for repeated monitoring of newborns. 

✅ Stable & Accurate Measurement: Xenon flash lamp with built-in UV cut filter to protect infant skin. RSD<2% for reliable repeatability. 

✅ Dual Measuring Units: Freely switch between mg/dL and μmol/L, compatible with global clinical standards. 

✅ Intelligent Data Processing: Automatically calculate average value from 2-5 readings; allow deletion of abnormal error data. 

✅ Backlit LCD Screen: Clear reading even during night ward rounds. 

✅ Handheld & Portable: Powered by rechargeable AAA Ni-MH batteries. Over 800 measurements per full charge. Auto power-off after 5 mins idle. Built-in self-calibration function for long-term stability.

 

Specifications

ModelYH-D-I
Measuring  MethodLight reflection                                                  
Light SourceXenon flash lamp
Display1.6 inch LCD display
Measuring Range0.0~29.9mg/dL(0.0~425μmol/L)
Indication Error±1 mg/dL (0~15 mg/dL); ±1.5 mg/dL (16~25 mg/dL)
Measuring AccuracyRSD<2%
Power Supply4×AAA rechargeable Ni-MH batteries
Battery Life≥800 tests per full charge

 

FAQ

Q: Does this bilirubin meter need blood collection? 

A: No. It is non-invasive transcutaneous measurement, just touch skin with probe. 

Q: Can I switch measuring units? 

A: Yes, support mg/dL and μmol/L switch freely. 

Q: Does the machine have self-calibration? 

A: Yes, built-in self-calibration function to ensure stable measurement. 

Q: What is the warranty period? 

A: 1-year warranty for main unit.