YH-9800D High Frequency Mammography Unit
这里是标题一h1占位文字
Classification :
Application:
Mammography Unit is a X-ray apparatus involving in various advanced technologies, specially designed for the diagnosis of mammary gland diseases. It is sensitive to mammary gland lump, calcification, protuberance and carcinogensis and first-choice apparatus for the image examination of mammary diseases in medical institutes.
Main Parameters:
(IAE C339V tube)
Note: Beside the IAE tube, you can also choose Varian Tube Chinese Tube
1. X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type: High Frequency Inverter 80kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating: 6.2kW
2. X-ray Tube
Model: IAE C339V
Focal Spot Size: Dual Focus 0.1/0.3mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 10°/16°
Anode Heat Storage: 210kJ (300kHU)
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
3. Radiographic Stand
C-ARM: Vertical Movement: 590mm
Center of electric rotating C-arm, automatic return function by one key
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
Rotations Deg:+90°~-90°
SID: 650mm
4. Cassette Image Receptor
18*24cm (24cm*30cm optional)
Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)
Grid Ratio: 5:1, 30 Line/cm
5. Line Voltage
220Vac@25A, Single phase
6. Weight and Size:
240kg(Gross weight: 340kg)
L*W×H: 940mm*560mm*2000mm
Upgrading(DR System):
Above introduction for YH-9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.
| Main Parameters for Full Digital Mammography System | ||
| Name | Parameters | |
| Specialized Digital Flat Panel Detector for Mammography | Detector, Power Box, Date Line, Capture Card, etc | |
| Effective Coverage of Detector | 23*15cm, 29*23cm | |
| Pixel Matrix | 3072*1944, 3888*3072 | |
| Limit of Spatial Resolution | 6.0Lp/mm | |
| DQE Value | 70% | |
| Dynamic Range | 14bit digital output | |
| Pixel Size | 75um | |
| High Voltage Synchronizer | BNC | |
| Output | Camera Link or Ethernet | |
| Working Condition | 10-40℃ | |
| Storage Environment | -10-50℃ | |
| Bucky | Housing and Movement Device | |
| Size | 370*275*125cm | |
| Stepless Speed Regulating Range | 0-6cm/s | |
| Movement Range | 0.5-2cm | |
| Grid | ||
| Size | 24*30cm | |
| Grid Ratio | 3.5:1 | |
| Focal Distance | 65cm | |
| Software | ||
| Workstation | Standard Detector Image Acquisition Workstation | |
| CPU≥Intel Duo Core 2.60GHz | ||
| Hardware≥250G | ||
| Memory≥2G | ||
| Display Card≥512MB | ||
| 19’’ High Brightness High Contrast LCD, 1280*1024 Pixel Resolution | ||
| Network Interface Worklist | ||
| DICOM3.0 Transmission | ||
| 100/1000 Gigabit Ethernet | ||
Sample Films: