• YH-6100X Anesthesia Machine
YH-6100X Anesthesia Machine

YH-6100X Anesthesia Machine

这里是标题一h1占位文字

1.Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient. 2.Safety design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.

Classification :

Features:

1.Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.

2.Safety design: Vaporizer with temperature, pressure, flow compensation

and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.

3.Alarm: 13 alarms to make sure the safety. Three level alarm system, visual and sound alarm information.

Built-in battery ensure 2-3 hours using when power failure.

4.Visible self-checking system: Make sure the safety of all parts.

5.Before setting parameters, choose freely type of patients: adult, children and neonatal. Also preset the age of patient.

6.Separate design of electric circuit and gas circuit ensure long using life.

7.Language: 8 languages for exchange including Chinese, English, Spanish, French, Russian, Turkish, German, Portuguese.

Ventilation mode

CMV, V-CMV, P-SIMV, V-SIMV, PSV, PRVC, SIGH, MANUAL

Ventilator parameter range

Tidal volume(Vt)   0, 10 mL ~ 1500 mL

Frequence(Freq)   4 /min ~ 100 /min

I:E   4:1 ~ 1:10

PEEP   0 cmH2O ~ 30 cmH2O

Rapid oxygen supply   25 L/min ~ 75 L/min

Pressure trigger   -1 cmH2O ~ -20 cmH2O

Flow trigger   0.3 L/min,1 L/min ~ 15 L/min

Pressure support   3 cmH2O ~ 50 cmH2O

Pressure limit   10 cmH2O ~ 100 cmH2O

Inspiration apnea   OFF, 5 % ~ 60 %

Inspiration time   0.2 s ~ 5 s

Trigger   5 % ~ 95 %

SIMV frequency   4 /min ~ 60 /min

Rise time   0 s ~ 2 s

Monitoring parameter

Frequence(Freq)   0 /min ~ 100 /min

Tidal volume (Vt)   0 mL ~ 2500 mL

Minute volume   0 L/min ~ 99.9 L/min

Oxygen concentration   15 % ~ 100 %

Airway pressure   -20 cmH2O ~ 100 cmH2O

Inspiration platform pressure   0 cmH2O ~ 100 cmH2O

PEEP   0 cmH2O ~ 70 cmH2O

I:E   4:1 ~ 1:10

Alarm and protection

VT upper limit 5 mL ~ 2000 mL

VT lower limit 0 mL ~ 1995 mL

MV upper limit 0.1 L/min ~ 100 L/min

MV lower limit 0.0 L/min ~ 99.9 L/min

Respiration frequency upper limit 2 /min ~ 100 /min

Respiration frequency lower limit 0 /min ~ 98 /min

FIO2 upper limit 20 % ~ 100 %

FIO2 lower limit 18 % ~ 98 %

Airway pressure upper limit 2 cmH2O ~ 100 cmH2O

Airway pressure lower limit 0 cmH2O ~ 98 cmH2O

Apnea 20 s ~ 40 s

Oxygen concentration never lower than 25% when N2O start

Testing

Automatic leakage compensation testing

Patient circuit leakage compensation and automatic compliance compensation

Patient monitor and AG monitor can be equipped

Manual ventilation, mechanical ventilation and standby

Oscillogram: P-T, F-T, V-T, Lung function loop, ETCO2

Self-testing visible

Alarm visible

ACGO function

Oscillogram

P-T (pressure-time)

F-T (flow-time)

V-T (volume-time)

ETCO2 -T (ETCO2 -time)

P-V loop (pressure-volume loop)

F-V loop (flow-volume loop)

F-P loop (flow-pressure loop)