YH-6100X Anesthesia Machine
这里是标题一h1占位文字
Classification :
Features:
1.Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
2.Safety design: Vaporizer with temperature, pressure, flow compensation
and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
3.Alarm: 13 alarms to make sure the safety. Three level alarm system, visual and sound alarm information.
Built-in battery ensure 2-3 hours using when power failure.
4.Visible self-checking system: Make sure the safety of all parts.
5.Before setting parameters, choose freely type of patients: adult, children and neonatal. Also preset the age of patient.
6.Separate design of electric circuit and gas circuit ensure long using life.
7.Language: 8 languages for exchange including Chinese, English, Spanish, French, Russian, Turkish, German, Portuguese.
Ventilation mode
CMV, V-CMV, P-SIMV, V-SIMV, PSV, PRVC, SIGH, MANUAL
Ventilator parameter range
Tidal volume(Vt) 0, 10 mL ~ 1500 mL
Frequence(Freq) 4 /min ~ 100 /min
I:E 4:1 ~ 1:10
PEEP 0 cmH2O ~ 30 cmH2O
Rapid oxygen supply 25 L/min ~ 75 L/min
Pressure trigger -1 cmH2O ~ -20 cmH2O
Flow trigger 0.3 L/min,1 L/min ~ 15 L/min
Pressure support 3 cmH2O ~ 50 cmH2O
Pressure limit 10 cmH2O ~ 100 cmH2O
Inspiration apnea OFF, 5 % ~ 60 %
Inspiration time 0.2 s ~ 5 s
Trigger 5 % ~ 95 %
SIMV frequency 4 /min ~ 60 /min
Rise time 0 s ~ 2 s
Monitoring parameter
Frequence(Freq) 0 /min ~ 100 /min
Tidal volume (Vt) 0 mL ~ 2500 mL
Minute volume 0 L/min ~ 99.9 L/min
Oxygen concentration 15 % ~ 100 %
Airway pressure -20 cmH2O ~ 100 cmH2O
Inspiration platform pressure 0 cmH2O ~ 100 cmH2O
PEEP 0 cmH2O ~ 70 cmH2O
I:E 4:1 ~ 1:10
Alarm and protection
VT upper limit 5 mL ~ 2000 mL
VT lower limit 0 mL ~ 1995 mL
MV upper limit 0.1 L/min ~ 100 L/min
MV lower limit 0.0 L/min ~ 99.9 L/min
Respiration frequency upper limit 2 /min ~ 100 /min
Respiration frequency lower limit 0 /min ~ 98 /min
FIO2 upper limit 20 % ~ 100 %
FIO2 lower limit 18 % ~ 98 %
Airway pressure upper limit 2 cmH2O ~ 100 cmH2O
Airway pressure lower limit 0 cmH2O ~ 98 cmH2O
Apnea 20 s ~ 40 s
Oxygen concentration never lower than 25% when N2O start
Testing
Automatic leakage compensation testing
Patient circuit leakage compensation and automatic compliance compensation
Patient monitor and AG monitor can be equipped
Manual ventilation, mechanical ventilation and standby
Oscillogram: P-T, F-T, V-T, Lung function loop, ETCO2
Self-testing visible
Alarm visible
ACGO function
Oscillogram
P-T (pressure-time)
F-T (flow-time)
V-T (volume-time)
ETCO2 -T (ETCO2 -time)
P-V loop (pressure-volume loop)
F-V loop (flow-volume loop)
F-P loop (flow-pressure loop)