Waveform: BiphasicCharge Time: Less than 7 seconds with a new fully charged battery.Energy Display: Monitor display indicates both selected and delivered energy.Charge Prompt Type: Voice and visual prompts.Electrode lmpedance Measurement Range: 0-250 ohms.

Classification :

Specification

Display

Display Type: 8 inch high resolution LCD displaySweep Speed:25mm/secInformation: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Se-lection and Limits, Delivered Energy.

Defibrillator

Waveform: BiphasicCharge Time: Less than 7 seconds with a new fully charged battery.Energy Display: Monitor display indicates both selected and delivered energy.Charge Prompt Type: Voice and visual prompts.Electrode lmpedance Measurement Range: 0-250 ohms.

ECG Monitoring

Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.Lead Selection: Displayed on monitor, paddles, l, l, ll, AVR, AVL, AVF, V.ECG Size: 0.25, 0.5,1,1.5,2, 4 cm/mV diplay on monitor.Heart Rate:20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor, user-selectableSmart Alarms: Beeper/voice prompts indicate shockable rhythm.

Recorder

Paper: 50mm thermal.

Speed:12.5mm/sec,25mm/sec,50mm/sec.User-selectable 6-second delay.

Printing Method: High-resolution, thermal print head.

Print-out Modes: Manual or automatic, user-configurable.

On/Off Control: Front panel and paddle.

Automatic Function: 9-seconds recording initiated by alamm activation or defibrillator chargeor defibrillator discharge.

Battary

Type: Rechargeable, Ni-MH battery, 12V.

Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximumenergy, or 3 hours minimum of continuous ECG monitoring.Additional parameters will effect operating time with different functions.

AED Mode

AED Function: Auto analyze and charge X3 with programmable auto energy level selection,screen prompts, and voice prompts.

Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardiawith rates >=140bpm,

and QRS complex wave duration >=140ms.

Charge Control: Control on device front panel, press key on paddlePrompts: Voice and visual prompts.

Manual Mode

Energy Selection: Selectable at 2,5,7,10,20,30,50,70,100,150,200,300, 360 joules.Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" messagedisplayed on monito

Specification

Specification MB_pacer (Optional)
Type VVI
Pulse Type rectangular,constant current
Pulse Amplitude 0 to 180 mA ± 10% or 5 mA (whichever is greater).
Pacing Rate Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode (MFE)Pads multipurpose defibrillation/pacing electrodes
Pause Pacing pulse frequency reduced by a factor of 4 when activated
Refractory Period NC(VVI demand do not have this specification)
Pulse Width (20+ 1.5 ms)
Output Protection Fully defibrillator protected and isolated

 

Specification MB_EtCO2 (Optional)
Type of sensor Sidestream
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40 °C to 70°C, <90% RH, non-condensing
Operating conditions 5 °C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5 V±5% (max ripple 200 mVp-p)
TDP Typical value120mA Excursion calibration typical value280mA
Range 0-19.7% (0 –150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0 - 40 mmHg ± 2 mmHg41 - 70 mmHg ± 5% of reading71 - 100 mmHg ± 8% of reading101 - 150 mmHg ± 10% of reading
Respiratory rate 2-150 BPM
Respiratory rate measurement accuracy 1% ±1BPM

 

Specification MB_NIBP (Optional)
Measurement Technology Oscilloscope OPE measure
Parameters Display Systolic, diastolic and mean pressure
Measurement Mode Manual, Auto and Sequence(Adult Mode)
Resolution 1 mmHg
NIBP Range, Accuracy: Systolic Pressure: 0kPa ~ 34kPa(0mmHg ~ 255mmHg); Accuracy: ±0.5kPa (±4mmHg)Diastolic Pressure: 2kPa ~ 26 kPa(15mmHg ~ 195mmHg); Accuracy: ±0.5kPa (±4mmHg)Mean blood pressure: 2.67kPa~31.3kPa(20mmHg~235mmHg); Accuracy: ±0.5kPa (±4mmHg)

 

Specification 

Pressure accuracy ±0.5kP(±4mmHg)
Pressure range 0kPa(0mmHg)~40kPa(300mmHg)
Alarm range can be set Systolic Pressure: 0kPa~40kPa(0mmHg~300mmHg)Diastolic Pressure: 0kPa~26.7kPa(0mmHg~200mmHg)Mean blood pressure: 0kPa~40.0kPa(0mmHg~300mmHg)
Alarm accuracy Not exceeding the set value ±10%
Alarm Time No more than 12s

 

Specification SPO2 Moudle (Optional)
Measurement Range: 30 ~100%,±2% between 80%~90%,Others ±5%
Alarm Range User set high limit and low limit
Alarm Accuracy ±10 within setting values.
Alarm Time Accuracy Less than 12 sec.

 

 

 