• DM6B Veterinary Anesthesia Machine
DM6B Veterinary Anesthesia Machine

DM6B Veterinary Anesthesia Machine

这里是标题一h1占位文字

Gas supply Gas source O2(For medical use) Input pressure range 280 kPa~600 kPa Output pressure of regulator

Classification :

Gas supply

Gas source: O2(For medical use)

Input pressure range: 280 kPa~600 kPa

Output pressure of regulator

(gas cylinder supply)  less than 440 kPa

Safety valve: 780kPa

Negative pressure air source: ≥75 L/min

Flow rate 

Adjust range of flow meter

O2  0 L/min~5 L/min

precision (20℃ 101.3kPa,supply pressure 440 kPa)

The precision from 10 % of full scale to full scale is ±10 % of indicated value

The precision lower than 10 % of full scale is class 4.

Flow rate of oxygen flush valve: 25 L/min~ 75 L/min  

Output pressure for fresh valve: 30 kPa ~ 45 kPa      

Power supply

Voltage: 100-240 V ~

Frequency: 50/60 HZ

Input power: 40VA

Fuse

Main power: T2AH 250V

Internal power: T4AH 250V

Ventilation mode

IPPV

A/C

SIMV

Ventilation parameters

Specification

Frequency

Adjusting range: 1 bpm ~ 100 bpm

(Under SIMV:1 bpm~ 20 bpm All mode except SIMV: 4 bpm~100 bpm)

Allowable error: ± 15 %   

Inhalation time (I:E) (Tinsp)  

Adjusting range  2:1(1:0.5) ~ 1:6 (0.2s ~ 6.0s)

Allowable error ± 15 % or ± 0.1s, whichever is the greater

Tidal volume (VT)

Adjusting range 0,20 mL ~ 1500 mL

Minute ventilation (MV) 

Max MV  ≥18 L/min

PEEP(optional)

Adjusting range  0 kPa ~ 3kPa

Allowable error  ± 15 % or ±(0.3 kPa+10%setting value), whichever is the greater

Pressure trigger(PTr)

Adjusting range - 2.0 kPa ~ 0kPa(Under PEEP) 

Allowable error  ±(0.1 kPa+10 %setting value)

Flow trigger(FTr)

Adjusting range  OFF, 0.5 L/min ~ 30 L/min

Allowable error  >3L/min:±20% ≤3L/min:±0.6 L/min

Holding time(Inhalation platform)(TIP)

Adjusting range 0 ~ 3s(Less than 50% of inhalation time)

Allowable error ± 15 % or± 0.1 s,whichever is the greater

Sigh

Adjusting range  0.1/100 ~ 5/100

Apnea ventilation

Adjusting range  OFF, 5 s ~ 60 s

Max set working pressure

pressure limit range 0.3kPa ~ 10kPa

Allowable error  ± 15 % or ±(0.2kPa+10%setting value), whichever is the greater

Max pressure  ≤12.5 kPa

explanation:

1 set pressure limit value to produce maximum working pressure( the upper limit of high airway pressure alarm).

2 do not use negative pressure at exhalation.

3 maximum limit pressure is pressure of the safety valve.

Driven gas

Gas source  O2(For medical use)

Input pressure range  280 kPa~600 kPa

Fresh gas compensation

  1. Compensation range  0~15 L/min

  2. gas composition  O2 and anaesthetic

Ventilation parameter Monitoring 

The fllowing are monitoring parameters under the environment of body temperature and pressure-saturated.  

Minimum exhalation volume maybe monitored is 50 mL/min.

display:

Parameter

Range

Resolving power

Accuracy

Frequency(Freq)

0 bpm ~ 100 bpm

1 bpm

±15 %

Tidal volume(VT)

0~ 2000 mL

10 mL

>100 mL ,  ±20% ≤100 mL,  ±0.02 L

Minute ventilation(MV)

0~100L/min

0.1 L/min

>1L/min,  ±20% ≤1L/min,  ±0.5 L/min

(Ppeak)

0~100 cmH2O

1 cmH2O

±(4%full scale+4%actual reading)

O2 concentration(optional)

15 % ~ 100 %

0.1 %

±[ 2.5 %(v/v)+2.5 %(concentration level)]

Compliance

1~1000mL/ cmH2O

1mL/ cmH2O

 

Waveform display:

Time- airway pressure(under all modes)

Time—flow(under all modes)

pressure volume loop(all modes)

Remarks:The machine cannot record all the adjusting and monitoring values.